Airflow Meter
- Turn ignition off. Disconnect the airflow meter connector. Using a DVOM, measure resistance between the appropriate airflow meter terminals. See Fig 1. For resistance specifications, refer to the AIRFLOW METER RESISTANCE table.
AIRFLOW METER RESISTANCE
| Terminals |
Ohms |
°F (°C) |
| VS & E2 |
200-600 |
N/A |
| VC & E2 |
200-400 |
N/A |
| THA & E2 |
10,000-20,000 |
-4 (-20) |
| THA & E2 |
4000-7000 |
32 (0) |
| THA & E2 |
2000-3000 |
68 (20) |
| THA & E2 |
900-1300 |
104 (40) |
| THA & E2 |
400-700 |
140 (60) |
| FC & E1 |
Infinity |
N/A |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
- Using a DVOM, measure resistance between airflow meter terminals while moving airflow measuring plate inside airflow meter. For specifications, see AIRFLOW METER MEASURING PLATE RESISTANCE table. See Fig 1.
AIRFLOW METER MEASURING PLATE RESISTANCE
| Terminals |
Ohms |
Measuring Plate Position |
| FC & E1 |
Infinity |
Fully Closed |
| FC & E1 |
Zero |
Other Than Closed |
| VS & E2 |
200-600 |
Fully Closed |
| VS & E2 |
20-1000 |
Fully Open |