Diode Assembly
- With diode (rectifier) assembly on bench, connect ohmmeter positive lead to each rectifier terminal and negative lead to positive (+) terminal. See Fig 1. Reverse ohmmeter leads and check again. Continuity should exist in one direction and not exist in the other.
- Connect ohmmeter positive lead to each rectifier terminal and negative lead to each negative (-) terminal. Reverse ohmmeter leads and check again. Continuity should exist in one direction and not exist in the other. If continuity is not as specified, replace diode assembly.
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002