Display Resets When Ignition Is Turned Off
- Check DOME fuse. If DOME fuse is okay, go to next step. If DOME fuse is blown, replace it. If DOME fuse blows again, disconnect instrument cluster connector "A". See Figure. Replace DOME fuse. If DOME fuse blows again, repair circuit between DOME fuse and instrument cluster. If DOME fuse does not blow again, replace circuit plate.
- Disconnect instrument cluster connectors "A" and "C". See Figure. Check voltage at terminal No. 1 of instrument cluster connector "C". See Figure or Figure. If battery voltage is not present, repair circuit between DOME fuse and instrument cluster. If battery voltage is present, replace circuit plate.