Circuit Description
Battery voltage is supplied to BATT terminal at ECM at all times. This circuit is used by diagnostic trouble code memory and air/fuel ratio adaptive control value memory. Code is set is there is an open in backup power source circuit. Possible causes are:
- Open in backup power source circuit.
- ECM malfunction.