Load Test
NOTE:
If battery is fully charged, disable ignition system. Crank engine for about 15 seconds to partially discharge battery.
- Connect an ammeter as described in NO-LOAD TEST , step 1). See Figure. Start engine. Turn on high beam headlights and place heater blower control on HI. Increase engine speed to 2000 RPM.
- Check ammeter reading. Ammeter should read 30 amps or more. If amperage is less than specified, repair or replace generator.
GENERATOR RATED AMPERE OUTPUT SPECIFICATIONS
| Application | (1) Amperes | ||
|---|---|---|---|
| LX450 | 80 | ||
|
|||