Power Mirror Switch Test
Remove power mirror switch. Check for continuity between specified terminals at switch. See Fig 1. See POWER MIRROR SWITCH CONTINUITY TEST table. If continuity does not exist, replace switch.
POWER MIRROR SWITCH CONTINUITY TEST
| Switch Position | Terminals | |||
|---|---|---|---|---|
| Left Switch | ||||
| Off (Neutral) | (1) | |||
| Up | 3 & 4; 7 & 8 | |||
| Down | 4 & 7; 3 & 8 | |||
| Left | 4 & 9; 7 & 8 | |||
| Right | 4 & 7; 8 & 9 | |||
| Right Switch | ||||
| Off (Neutral) | (1) | |||
| Up | 1, 7 & 8; 2 & 4 | |||
| Down | 1, 2 & 8; 4 & 7 | |||
| Left | 1, 7 & 8; 4 & 10 | |||
| Right | 2, 8 & 10; 4 & 7 | |||
|
||||