Door Unlock Detection Switch Circuit
Remove door trim to access door lock motor assembly. Disconnect switch connector. Check continuity between terminal No. 1 (Blue/White wire LH, Pink/Black wire RH) and No. 4 (White/Black wire) with door unlocked. Continuity should exist. Check continuity with door locked. Continuity should not exist. If continuity is not as specified, replace switch. If continuity is as specified, check wiring between switch, ECU and ground. Repair as needed. If wiring is okay, check ECU. See PIN VOLTAGE TESTS . If found to be defective, replace ECU and retest system.