Measure resistance between specified terminals of distributor connector. See DISTRIBUTOR PICK-UP COIL RESISTANCE  table. See Fig 1. If resistance is not as specified, replace distributor housing assembly.

DISTRIBUTOR PICK-UP COIL RESISTANCE

Application Ohms
Cold (1)
Between Terminals G1 & "G-" 125-200
Between Terminals G2 & "G-" 125-200
Between Terminals NE & "G-" 155-250
Hot (2)
Between Terminals G1 & "G-" 160-235
Between Terminals G2 & "G-" 160-235
Between Terminals NE & "G-" 190-290
(1) Sensor temperature of 14-122°F (-10-50°C).
(2) Sensor temperature of 123-212°F (51-100°C).
Fig 1: Identifying Distributor Connector Terminals