Confirmation Test (Using Oscilloscope)
- To test bank No. 1 and 2 oxygen sensors No. 1, backprobing, connect oscilloscope between ECM E13 connector terminal No. 17 (White/Black wire) and terminals No. 12 (Black wire) and No. 11 (White wire). To test bank No. 1 and 2 oxygen sensors No. 2. Backprobing, connect oscilloscope between ECM E13 connector terminal No. 17 (White/Black wire) and ECM E11 connector terminals No. 18 (Green wire) and No. 27 (Yellow wire).
- Ensure all accessories are turned off. Start and warm engine to normal operating temperature. Increase engine speed to 2500-3000 RPM for 3 minutes. Using oscilloscope, ensure heated oxygen sensors (bank 1 and 2 sensor 1 and 2) feedback to ECM fluctuates around .5 volt and are different from each other. See Figure.