Confirmation Test (Using Oscilloscope)
- To test banks No. 1 and 2 oxygen sensors No. 1, backprobing, connect oscilloscope between ECM E16 harness connector terminal No. 17 (White/Red wire) and terminals No. 12 (White wire) and No. 11 (Red/Blue wire). To test bank No. 1 and No. 2 oxygen sensors No. 2, backprobing, connect oscilloscope between ECM E16 connector terminal No. 17 (White/Red wire) and ECM E18 harness connector terminal No. 8 (White wire), and between ECM E16 harness connector terminal No. 17 (White/Red wire) and ECM E20 harness connector terminal No. 24 (Green wire).
- Ensure all accessories are turned off. Start and warm engine to operating temperature. Increase engine speed to 2500-3000 RPM for 3 minutes. Using oscilloscope, ensure heated oxygen sensors (bank 1 and 2 sensor 1 and 2) feedback to ECM fluctuates around .5 volt and are different from each other. See Figure.