LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 1999 >> SC 400 V8-4.0L (1UZ-FE) >> Repair and Diagnosis >> Body and Frame >> Locks >> Power Locks >> Power Door Lock Control Module >> Testing and Inspection >> Component Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Component Inspection






INSPECT THEFT DETERRENT AND DOOR LOCK CONTROL ECU OPERATION
a. With the connectors connected, shut all doors.
b. Check that there is 10 V - 14 V between terminal B8 and ground when the ignition switch is turned ON.
c. After turning the ignition switch OFF, check within 60 seconds that there is battery positive voltage between terminal B8 and ground.
d. Turn the ignition switch ON then OFF, and check that there is 10 V - 14 V between terminal B8 and ground when the ignition is switched OFF.
e. Open the front door within 60 seconds of turning the ignition off and check that there is no voltage between terminal B8 and ground.
f. Close all the doors and turn the ignition switch ON.
g. When a front door is opened, check that there is battery positive voltage between terminal B8 and ground.
h. Check that there is no voltage between terminal B8 and ground when the ignition switch is turned to OFF.
If operation is not as specified, replace the ECU.