Door Open Detection Switch
Remove door open detection switch. Using an ohmmeter, check continuity between detection switch terminals No. 3 (Green/White wire) and No. 6 (Black wire). See WIRING DIAGRAMS . Continuity should exist with switch pin released. Continuity should not exist with switch pin pressed. If continuity is not as specified, replace detection switch and retest system operation.