Driver's Window Up Operation
Disconnect window motor harness connector. Connect ohmmeter positive lead to terminal No. 4 (White/Green wire) and negative lead to terminal No. 5 (Brown/Black wire) at window motor harness connector. Apply positive battery voltage to terminal No. 1 (Red Wire) and negative battery lead to terminal No. 2 (Green wire) at window motor harness connector. See Figure. Ensure continuity is present when window goes up, and not present when window is fully closed. If continuity is not as specified, replace window motor assembly.