Right Front Door
- Remove door lock control switch from front door. Connect ohmmeter between terminals No. 2 (White/Black wire) and No. 3 (Light Green/Black wire) of door lock control switch connector (component side). See WIRING DIAGRAMS . With door lock control switch in lock position, continuity should exist. With door lock control switch in unlock position, continuity should not exist.
- Connect ohmmeter between terminals No. 2 (White/Black wire) and No. 1 (Light Green/Red wire) of door lock control switch connector (component side). See WIRING DIAGRAMS . With door lock control switch in unlock position, continuity should exist. With door lock control switch in lock position, continuity should not exist. If continuity is not as specified, replace door lock control switch and retest system operation.