ELECTROCHROMIC Outer Mirror
Disconnect outer mirror connector. Using jumper wires, connect 1.5 volt dry cell battery positive lead and battery negative lead to specified terminals at mirror connector. See ELECTROCHROMIC OUTER MIRROR TEST table. See Figure-Figure . Mirror face should change from bright to dark. Replace mirror assembly as necessary.
ELECTROCHROMIC OUTER MIRROR TEST
| Application | (1) Battery Positive To Terminal No. | (1) Battery Negative To Terminal No. | |||
|---|---|---|---|---|---|
| GS300 & GS430 | |||||
| With Memory | 5 | 4 | |||
| Without Memory | 2 | 1 | |||
| LX470 | 2 | 3 | |||
| RX300 | 2 | 1 | |||
|
|||||