ELECTROCHROMATIC Outer Mirror
Disconnect outer mirror connector. Using jumper wires, connect 1.5 volt dry cell battery positive lead and battery negative lead to specified terminals at mirror connector. See ELECTROCHROMATIC OUTER MIRROR TEST table. Mirror face should change from bright to dark. Replace mirror assembly as necessary.
ELECTROCHROMATIC OUTER MIRROR TEST
| Application | (1) Battery Positive To Terminal No. | (1) Battery Negative To Terminal No. | |||
|---|---|---|---|---|---|
| With Memory | 4 | 3 | |||
| Without Memory | 2 | 1 | |||
|
|||||