Front Passenger's Window Up Operation
Disconnect window motor harness connector. Connect ohmmeter positive lead to window motor harness connector terminal No. 6 (Black/White wire) and negative ohmmeter lead to terminal No. 1 (Brown/White wire). Apply positive battery voltage to window motor harness connector terminal No. 4 (Red/Green wire) and connect negative battery lead to terminal No. 5 (Green wire). See Figure. Ensure continuity exists when window goes up, and does not exist when window is fully closed. If continuity is not as specified, replace window motor assembly.