Starter Control Circuit
With ignition switch in START position, current flows to Park/Neutral Position (PNP) switch. PNP switch prevents the starter from operating if the transmission is in gear. Current flows through the starter relay coil to ground. This energizes the starter relay, allowing battery power to the starter solenoid. The starter solenoid engages, allowing current to flow through starter motor field coils.