Power Window Master Switch Circuit
- Disconnect the connectors from the power window master switch and inspect the connector on the wiring harness side. See CONNECTOR IDENTIFICATION . See INSPECTING POWER WINDOW MASTER SWITCH CIRCUIT table. If the circuit is not as specified, replace the switch. See Figure.INSPECTING POWER WINDOW MASTER SWITCH CIRCUIT
Tester Connection Condition Specified Condition 9 - Ground Constant Continuity 1, 5 - Ground Constant B+ Voltage 2, 4 - Ground Ignition Switch LOCK No Voltage 2, 4 - Ground Ignition Switch ACC Or ON B+ Voltage - Inspect the power window master switch circuit. See POWER WINDOW MASTER SWITCH CIRCUIT under CIRCUIT TESTS in appropriate BODY CONTROL SYSTEM article.