Auto Operation (Driver's Window)
When the power window master switch is operated to AUTO UP position with the ignition on, the current flows from the D FR P/W fuse to the power window master switch TERMINAL 1 to TERMINAL 8 to the front LH power window motor TERMINAL 1 to TERMINAL 2 to the power window master switch TERMINAL 20 to TERMINAL 9 to GROUND, and the motor rotates to close the window. The motor continues to rotate until the window is fully closed or the DOWN position of the power window master switch is operated.
When the power window master switch is operated to AUTO DOWN position with the ignition on, the current flows from the D FR P/W fuse to the power window master switch TERMINAL 1 to TERMINAL 20 to the front LH power window motor TERMINAL 2 to TERMINAL 1 to the power window master switch TERMINAL 8 to TERMINAL 9 to GROUND, and the motor rotates to open the window. The motor continues to rotate until the window is fully opened or the UP position of the power window master switch is operated.