Intermittent Simulation
To reproduce the conditions creating an intermittent fault, use the following methods:
- Lightly vibrate component. See VIBRATION METHOD .
- Heat component. See HEATING METHOD .
- Wiggle or bend wiring harness. See VIBRATION METHOD .
- Spray component with water. See WATER SPRINKLING METHOD .
- Remove vacuum from component.
- Apply vacuum to component. Monitor circuit/component voltage or resistance while simulating intermittent. If engine is running, monitor for Diagnostic Trouble Codes (DTCs). Use test results to identify a faulty component or circuit.
- If malfunction seems to occur when electrical load is high, turn on all electrical equipment including heater blower, headlights, rear window defogger, etc. and check of malfunction occurs.