SERVICE DATA

Battery Specific gravity at 20°C (68°F ) 1.25-1.29
Voltage at 20°C(68°F ) 12.5-12.9 V
Generator Rated output 12V 130A
Rotor coil resistance at 20 ° C (68 ° F) 2.3 - 2.7 ohm
Slip ring diameter STD 14.2 - 14.4 mm (0.559 - 0.567 in.)
Minimum 14.0 mm (0.551 in.)
Brush exposed length STD 10.5 mm (0.413 in.)
Minimum 4.5 mm (0.177 in.)
Charging circuit Without load STD amperage 10 A or less
STD voltage 13.2-14.8 V
With load STD amperage 30 A or less