Section 387 (Power Door Lock Control System): Inspection
- Master switch: INSPECT DRIVER'S DOOR LOCK CONTROL SWITCH CONTINUITY CONTINUITY SPECIFICATION
Switch position Tester connection Specified condition LOCK 3-4 Continuity OFF - No continuity UNLOCK 3-14 Continuity If continuity is not as specified, replace the switch.
- INSPECT PASSENGER'S DOOR LOCK CONTROL SWITCH CONTINUITY CONTINUITY SPECIFICATION
Switch position Tester connection Specified condition LOCK 3-2 Continuity OFF - No continuity UNLOCK 1-2 Continuity If continuity is not as specified, replace the switch.
- INSPECT DOOR KEY LOCK AND UNLOCK SWITCH CONTINUITY CONTINUITY SPECIFICATION
Switch position Tester connection Specified condition LOCK 1-2 Continuity OFF - No continuity UNLOCK 1-3 Continuity If continuity is not as specified, replace the switch.
- Front door: INSPECT DOOR UNLOCK DETECTION SWITCH CONTINUITY CONTINUITY SPECIFICATION
Switch position Tester connection Specified condition OFF (Door Lock set to LOCK) - No continuity ON (Door Lock set to UNLOCK) 1 - 4 Continuity If continuity is not as specified, replace the switch.
- Rear door: INSPECT DOOR UNLOCK DETECTION SWITCH CONTINUITY CONTINUITY SPECIFICATION
Switch position Tester connection Specified condition OFF (Door Lock set to LOCK) - No continuity ON (Door Lock set to UNLOCK) 1-4 Continuity If continuity is not as specified, replace the switch.
- Back door: INSPECT DOOR UNLOCK DETECTION SWITCH CONTINUITY CONTINUITY SPECIFICATION
Switch position Tester connection Specified condition OFF (Door Lock set to LOCK) - No continuity ON (Door Lock set to UNLOCK) 1 - 4 Continuity If continuity is not as specified, replace the switch.
- Back door: INSPECT DOOR UNLOCK DETECTION SWITCH CIRCUIT (See DOOR UNLOCK DETECTION SWITCH CIRCUIT )
- Front door: INSPECT DOOR LOCK MOTOR OPERATION
- Connect the battery positive (+) lead to terminal 3 and the battery negative (-) lead to terminal 2, and check that the door lock link moves to UNLOCK position.
- Reverse the polarity and check that the door lock link moves to LOCK position.
If operation is not as specified, replace the door lock assembly.
- Rear door: INSPECT DOOR LOCK MOTOR OPERATION
- Connect the battery positive (+) lead to terminal 3 and the battery negative (-) lead to terminal 2, and check that the door lock link moves to UNLOCK position.
- Reverse the polarity and check that the door lock link moves to LOCK position.
If operation is not as specified, replace the door lock assembly.
- Back door: INSPECT DOOR LOCK MOTOR OPERATION
- Connect the battery positive (+) lead to terminal 3 and the battery negative (-) lead to terminal 2, and check that the door lock link moves to UNLOCK position.
- Reverse the polarity and check that the door lock link moves to LOCK position.
If operation is not as specified, replace the door lock assembly.
- Backdoor: INSPECT DOOR LOCK MOTOR CIRCUIT (See DOOR LOCK MOTOR CIRCUIT )
- Front door: INSPECT PTC THERMISTOR OPERATION (Using an ammeter)
- Connect the battery negative (-) lead to terminal 2.
- Connect the ammeter positive (+) lead to terminal 3 and the ammeter negative (-) lead to the battery negative (-) terminal, and check that the current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.
- Disconnect the leads from terminals.
- Approximately 60 seconds later, connect the battery positive (+) lead to terminal 2 and the battery negative (-) lead to terminal 3, and check that the door lock moves to the LOCK position.
If operation is not as specified, replace the door lock assembly.
- Rear door:
INSPECT PTC THERMISTOR OPERATION (Using an ammeter)
- Connect the battery negative (-) lead to terminal 2.
- Connect the ammeter positive (+) lead to terminal 3 and the ammeter negative (-) lead to battery negative (-) terminal, and check that the current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.
- Disconnect the leads from terminals.
- Approximately 60 seconds later, connect the battery positive (+) lead to terminal 2 and the battery negative (-) lead to terminal 3, and check that the door lock moves to the LOCK position.
If operation is not as specified, replace the door lock assembly.
- Back door:
INSPECT PTC THERMISTOR OPERATION (Using an ammeter)
- Connect the battery negative (-) lead to terminal 2.
- Connect the ammeter positive (+) lead to terminal 3 and the ammeter negative (-) lead to battery negative (-) terminal, and check that the current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.
- Disconnect the leads from terminals.
- Approximately 60 seconds later, connect the battery positive (+) lead to terminal 2 and the battery negative (-) lead to terminal 3, and check that the door lock moves to the LOCK position.
If operation is not as specified, replace the door lock assembly.
- Front door:
INSPECT PTC THERMISTOR OPERATION (Using an ammeter with a current-measuring probe)
- Connect the battery positive (+) lead to terminal 3 and the battery negative (-) lead to terminal 2.
- Attach a current-measuring probe to either the positive (+) lead or the negative (-) lead, and check that the current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.
- Disconnect the leads from terminals.
- Approximately 60 seconds later, reverse the polarity, and check that the door lock moves to the LOCK position.
If operation is not as specified, replace the door lock assembly.
- Rear door:
INSPECT PTC THERMISTOR OPERATION (Using an ammeter with a current-measuring probe)
- Connect the battery positive (+) lead to terminal 3 and the battery negative (-) lead to terminal 2.
- Attach a current-measuring probe to either the positive (+) lead or the negative (-) lead, and check that the current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.
- Disconnect the leads from terminals.
- Approximately 60 seconds later, reverse the polarity, and check that the door lock moves to the LOCK position.
If operation is not as specified, replace the door lock assembly.
- Backdoor:
INSPECT PTC THERMISTOR OPERATION (Using an ammeter with a current-measuring probe)
- Connect the battery positive (+) lead to terminal 3 and the battery negative (-) lead to terminal 2.
- Attach a current-measuring probe to either the positive (+) lead or the negative (-) lead, and check that the current changes from approximately 3.2 A to less than 0.5 A within 20 to 70 seconds.
- Disconnect the leads from terminals.
- Approximately 60 seconds later, reverse the polarity, and check that the door lock moves to the LOCK position.
If operation is not as specified, replace the door lock assembly.