GS 430

TID $04: HO2S HEATER

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 1) Malfunction threshold for HO2S heater
1 02 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 2) Malfunction threshold for HO2S heater
TID $08: THERMOSTAT

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.625 and subtract 40 [°C] ECT sensor output when estimated ECT has reached to malfunction criterion Malfunction criterion for thermostat
FRONT HO2S VOLTAGE MONITOR

Test ID Description of TEST DATA Conversion Factor Unit Standard Values
$07 Minimum HO2 sensor (sensor 1) voltage Multiply by 0.005 V Less than maximum TEST LIMIT
$08 Maximum HO2 sensor (sensor 1) voltage Multiply by 0.005 V More than minimum TEST LIMIT
FRONT HO2S SLOW SLOPE MONITOR

TEST ID Description of TEST DATA Conversion Factor Unit Standard
$03 Low sensor voltage for switch time calculation (constant) Multiply by 0.005 V Same as TEST LIMIT.
$04 High sensor voltage for switch time calculation (constant) Multiply by 0.005 V Same as TEST LIMIT.
FRONT HO2S SLOW SLOPE MONITOR

TEST ID Description of TEST DATA Conversion Factor Unit Standard
$31 Average of Rich to Leen response time Multiply by 0.04096 Second Between minimum and maximum TEST LIMIT.
$32 Average of Rich to Leen response time Multiply by 0.04096 Second Between minimum and maximum TEST LIMIT.
FRONT HO2S FREQUENCY MONITOR

TEST ID Description of TEST DATA Conversion Factor Unit Standard
$38 Average time per cycle of HO2 sensor voltage Multiply by 0.04096 Second Between minimum and maximum TEST LIMIT.
REAR HO2S VOLTAGE MONITOR

Test IDs Description of TEST DATA Conversion Factor Units Standard Values
$07 Minimum HO2 sensor (sensor 1) voltage Multiply by 0.005 Volt Less than maximum TEST LIMIT
$08 Maximum HO2 sensor (sensor 1) voltage Multiply by 0.005 Volt More than minimum TEST LIMIT
REAR HO2S MONITOR VOLTAGE

Test IDs Description of TEST DATA Conversion Factor Units Standard Values
$31 Average time for HO2 sensor (sensor 1) output to switch from Lean to Rich Multiply by 0.04096 Second Less than maximum TEST LIMIT
$32 Average time for HO2 sensor (sensor 1) output to switch from Rich to Lean Multiply by 0.04096 Second Less than maximum TEST LIMIT.
REAR HO2S SLOW RESPONSE MONITOR

Test IDs Description of TEST DATA Conversion Factor Units Standard Values
$37 Time until HO2 sensor voltage drops to 0.2 V during fuel-cut Multiply by 0.04096 Second Less than maximum TEST LIMIT
$39S witch time for HO2 sensor voltage to drop from 0.35 V to 0.2 V during fuel-cut Multiply by 0.04096 Second Less than maximum TEST LIMIT
REAR H2OS ELEMENT MONITOR

Test IDs Description of TEST DATA Conversion Factor Units Standard Values
$81 Percentage of monitor time that HO2 sensor (sensor 2) voltage below 0.05V Multiply by 0.390 % Less than TEST LIMIT
$84 Percentage of monitor time that HO2 sensor (sensor 2) voltage 0.7 V or more Multiply by 0.390 % More than TEST LIMIT
$85 Continuous time that HO2 sensor (sensor 2) voltage 0.45 V or more Multiply by 0.26214 Second More than TEST LIMIT
$87 Percentage of monitor time that HO2 sensor (sensor 2) voltage 0.45 V or more Multiply by 0.390 % More than TEST LIMIT
TID $01: CATALYST - USING HO2S ON SENSOR 1 AND 2

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.0078 [no dimension] Catalyst deterioration level bank 1: Determined by waveforms of HO2S sensor 1 and sensor 2 Malfunction criteria for catalyst deterioration
TID $02: EVAP - VACUUM MONITOR

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.0916 [mmHg] Test value of EVAP VSV: Determined by fuel tank pressure change during vacuum introduction Malfunction criteria for EVAP VSV
1 $02 Multiply by 0.0458 subtract 2.93 [mmHg] Test value of bypass VSV: Determined by fuel tank pressure change at switching over bypass VSV Malfunction criteria for bypass VSV
0 $03 Multiply by 0.0458 [mmHg] Test value of 0.04 inch leak: Determined by fuel tank pressure change Malfunction criteria for 0.04 inch leak
0 $04 Multiply by 0.0458 [mmHg] Test value of 0.02 inch leak: Determined by fuel tank pressure change Malfunction criteria for 0.02 inch leak
1 $05 Multiply by 0.0458 subtract 2.93 [mmHg] Test value of canister closed valve (CCV): Determined by fuel tank pressure change at switching over CCV Malfunction criteria for CCV