Monitor Result

Refer to CHECKING MONITOR STATUS  for detailed information.

The test value and test limit information are described as shown in the following table. Check the monitor result and test values after performing the monitor drive pattern (see READINESS MONITOR DRIVE PATTERN  ).

TID $02: EVAP system - LEV II Vacuum monitor 

MONITOR RESULT

TLT CID Unit Conversion Description of Test Data Description of Test Limit
1 $01 Multiply by 0.183 (mmHg) Test value of EVAP VSV stuck close: Determined by fuel tank pressure change during vacuum introduction Malfunction criteria for EVAP VSV stuck closed
0 $02 Multiply by 0.0655 (seconds) Test value of EVAP VSV stuck open: Determined by duration that fuel tank pressure is higher than criteria Malfunction criteria for EVAP VSV stuck open
0 $03 Multiply by 0.0655 (seconds) Test value of canister closed valve (CCV): Determined by duration that fuel tank pressure is lower than criteria Malfunction criteria for Canister Closed Valve (CCV)
0 $04 Multiply by 0.0458 (mmHg) Test value 0.04 inch leak: Determined by fuel tank pressure change Malfunction criteria for 0.04 inch leak
0 $05 Multiply by 0.0458 (mmHg) Test value 0.02 inch leak: Determined by fuel tank pressure change Malfunction criteria for 0.02 inch leak