Typical Enabling Conditions
ENABLING CONDITIONS
| The monitor will run whenever the following DTCs are not present | See LIST OF DISABLE A MONITOR |
| Altitude | Below 2,400 m (8,000 ft) |
| Battery voltage | 11 V or more |
| Throttle position learning | Completed |
| FTP sensor | No malfunction |
| (Engine start IAT) - (Engine start ECT) | -7 to 11.1°C (-12.6 to 20°F) |
| EVAP VSV, CCV | Not operated by scan tool |
| Either of the following conditions 1 or 2 is met | - |
| 1. Purge duty cycle | 6 % or more when intake air amount is 12 g/sec or more |
| 2. Purge concentration for 30 seconds | -5 %/% or more when vehicle speed is less than 10 km/h (6 mph) |
| Refuel during EVAP system monitor | Not refueled with engine running |
| FTP before EVAP system monitor | -1.7 kPa (12.75 mmHg) or more |
| Engine start ECT | 4.4 to 35°C (40 to 95°F) |
| Engine start IAT | 4.4 to 35°C (40 to 95°F) |
| IAT | 4.4°C (40°F) or more |
| Vehicle speed | Steady speed |
| Fuel slosh | No sloshing (i.e., fairly smooth road) |
| Time after engine start | Below 50 minutes |
| FTP change before vacuum introduction | Minimum change |
| Fuel tank level | Below 90 % |