Inspection Procedure
- Check ECU-B2, GAUGE and DOOR (RL) fuse.
CHECK:
Check continuity of ECU-B2, GAUGE and DOOR (RL) fuse.
OK:
Continuity
- NG: Replace the failure fuse.
- OK: Go to next step.
- Check voltage between terminals BDR, CPUB, SIG and GND of rear left door ECU connector.
PREPARATION:
Turn ignition switch ON.
CHECK:
Measure voltage between terminals SIG, and GND.
OK:
Voltage: 10 - 14 V
PREPARATION:
- Turn ignition switch OFF.
- Disconnect the rear left door ECU connector.
CHECK:
Measure voltage between terminals BDR, CPUB and GND.
OK:
Voltage: 10 - 14 V
- OK: Proceed to next circuit inspection shown on problem symptoms table (See PROBLEM SYMPTOMS TABLE ).
- NG: Go to next step.
- Check wire harness and connector between ECU and body ground.
- NG: Repair or replace wire harness or connector.
- OK: Check and repair wire harness and connector between ECU and battery.