LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2005 >> IS 300 Base, Automatic >> Repair and Diagnosis >> Electrical >> Starter >> Starting System - Service Specifications >> Starting System >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

SERVICE DATA - STARTING

Starter Rated voltage and output power 12 V 1.4 kW
No-load characteristics Current 90 A or less at 11.5 V
rpm 3, 000 rpm or more
Brush length STD 15.5 mm (0.610 in.)
Minimum 10.0 mm (0.394 in.)
Spring installed load STD 17.6 - 23.5 N (1.8 - 2.4 kgf, 3.9 - 5.3 lbf)
Minimum 11.8 N (1.2 kgf, 2.6 lbf)
Commutator  
Diameter STD 30.0 mm (1.181 in.)
Minimum 29.0 mm (1.412 in.)
Undercut depth STD 0.6 mm (0.024 in.)
Minimum 0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Magnetic switch  
Contact plate for wear Maximum 0.9 mm (0.035 in.)
Starter relay Resistance 3 - 5 10 kΩ or higher
3 - 5 (Apply battery voltage to terminal 1 and 2) Below 1 Ω