Service Data
Service Data - Starting
| Starter | Rated voltage and output power | 12 V 1.4 kW | |
| No-load characteristics | Current | 90 A or less at 11.5 V | |
| rpm | 3,000 rpm or more | ||
| Brush length | STD | 15.5 mm (0.610 in.) | |
| Minimum | 10.0 mm (0.394 in.) | ||
| Spring installed load | STD | 17.6 - 23.5 N (1.8 - 2.4 kgf, 3.9 - 5.3 lbf) | |
| Minimum | 11.8 N (1.2 kgf, 2.6 lbf) | ||
| Commutator | |||
| Diameter | STD | 30.0 mm (1.181 in.) | |
| Minimum | 29.0 mm (1.412 in.) | ||
| Undercut depth | STD | 0.6 mm (0.024 in.) | |
| Minimum | 0.2 mm (0.008 in.) | ||
| Circle runout | Maximum | 0.05 mm (0.0020 in.) | |
| Magnetic switch | |||
| Contact plate for wear | Maximum | 0.9 mm (0.035 in.) | |
| Starter relay | Resistance | 3 - 5 | 10 kΩ or higher |
| 3 - 5 (Apply battery voltage to terminal 1 and 2) | Below 1 Ω | ||