Vapor Pressure Sensor: Inspection
- INSPECT POWER SOURCE VOLTAGE OF VAPOR PRESSURE SENSOR
- Disconnect the vapor pressure sensor connector.
- Turn the ignition switch ON.
- Using a voltmeter, measure the voltage between connector terminals VC and E2 of the wiring harness side.
Voltage: 4.5-5.5V
- Turn the ignition switch OFF.
- Reconnect the vapor pressure sensor connector.
- INSPECT POWER OUTPUT OF VAPOR PRESSURE SENSOR
- Turn the ignition switch ON.
- Disconnect the vacuum hose from the vapor pressure sensor.
- Connect a voltmeter to terminals PTNK and E2 of the ECM, and measure the output voltage under these conditions:
- Apply vacuum (2.0 kPa (15 mmHg, 0.59 in.Hg)) to the vapor pressure sensor.
Voltage: 1.3-2.1 V
- Release the vacuum from the vapor pressure sensor.
Voltage: 3.0-3.6 V
- Apply pressure (1.5 kPa (15 gf/cm2
, 0.22 psi)) to the vapor pressure sensor.
Voltage: 4.2-4.8 V
- Apply vacuum (2.0 kPa (15 mmHg, 0.59 in.Hg)) to the vapor pressure sensor.
- Turn the ignition switch OFF.
- Reconnect the vacuum hose to the vapor pressure sensor.