Service Data
Service Data-Cooling
| Thermostat | Valve opening temperature | 80 - 84°C (176 - 183°F) | |
| Valve lift | at 95°C (203°F) | 8.5 mm (0.335 in.) or more | |
| Radiator cap | Relief valve opening pressure | STD | 93 - 123 kPa (0.95 - 1.25 kgf/cm2 , 13.5 - 17.8 psi) |
| Minimum | 78 kPa (0.8 kgf/cm2 , 11.4 psi) | ||
| Electric cooling fan | Rotating amperage | at 20°C (68°F) | 8.5 - 11.5 A |
| Cooling No. 1 fan relay | Resistance | 3 - 5 | 10 kΩ or higher |
| 3 - 5 (Apply battery voltage to terminal 1 and 2) | Below 1 Ω | ||
| Cooling No. 2 fan relay | Resistance | 3 - 4 | Below 1 Ω |
| 3 - 4 (Apply battery voltage to terminal 1 and 2) | 10 kΩ or higher | ||
| 3 - 5 | 10 kΩ or higher | ||
| 3 - 5 (Apply battery voltage to terminal 1 and 2) | Below 1 Ω | ||
| Cooling No. 3 fan relay | Resistance | 3 - 5 | 10 kΩ or higher |
| 3 - 5 (Apply battery voltage to terminal 1 and 2) | Below 1 Ω | ||