LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2005 >> IS 300 Base, Standard >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> Cooling System >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

Service Data-Cooling

Thermostat Valve opening temperature 80 - 84°C (176 - 183°F)
Valve lift at 95°C (203°F) 8.5 mm (0.335 in.) or more
Radiator cap Relief valve opening pressure STD 93 - 123 kPa (0.95 - 1.25 kgf/cm2 , 13.5 - 17.8 psi)
Minimum 78 kPa (0.8 kgf/cm2 , 11.4 psi)
Electric cooling fan Rotating amperage at 20°C (68°F) 8.5 - 11.5 A
Cooling No. 1 fan relay Resistance 3 - 5 10 kΩ or higher
  3 - 5 (Apply battery voltage to terminal 1 and 2) Below 1 Ω
Cooling No. 2 fan relay Resistance 3 - 4 Below 1 Ω
  3 - 4 (Apply battery voltage to terminal 1 and 2) 10 kΩ or higher
  3 - 5 10 kΩ or higher
  3 - 5 (Apply battery voltage to terminal 1 and 2) Below 1 Ω
Cooling No. 3 fan relay Resistance 3 - 5 10 kΩ or higher
  3 - 5 (Apply battery voltage to terminal 1 and 2) Below 1 Ω