Service Data
EMISSION CONTROL - SERVICE DATA
| VSV for CCV | ||
| Resistance | 1 - 2 | 25 to 30 Ω at 20°C (68°F) |
| 1 - Body ground | 10 kΩ or higher | |
| 2 - Body ground | 10 kΩ or higher | |
| VSV for EVAP | ||
| Resistance | 1 - 2 | 27 to 33 Ω at 20°C (68°F) |
| 1 - Body ground | 10 kΩ or higher | |
| 2 - Body ground | 10 kΩ or higher | |
| VSV for ACIS | ||
| Resistance | 1 - 2 | 33 to 39 Ω at 20°C (68°F) |
| 1 - Body ground | 10 kΩ or higher | |
| 2 - Body ground | 10 kΩ or higher | |
| VSV for PSV | ||
| Resistance | 1 - 2 | 37 to 44 Ω at 20°C (68°F) |
| 1 - Body ground | 10 kΩ or higher | |
| 2 - Body ground | 10 kΩ or higher | |
| Heated oxygen sensor | ||
| Resistance | 1 (HT) - 2 (+B) | 11 to 16 Ω at 20°C (68°F) |