GS 430
TID $04: HO2S HEATER
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.000076 [A] | Maximum HO2S heater current (Bank 1 Sensor 1) | Malfunction threshold for HO2S heater |
| 1 | 02 | Multiply by 0.000076 [A] | Maximum HO2S heater current (Bank 1 Sensor 2) | Malfunction threshold for HO2S heater |
TID $08: THERMOSTAT
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.625 and subtract 40 [°C] | ECT sensor output when estimated ECT has reached to malfunction criterion | Malfunction criterion for thermostat |
FRONT HO2S VOLTAGE MONITOR
| Test ID | Description of TEST DATA | Conversion Factor | Unit | Standard Values |
|---|---|---|---|---|
| $07 | Minimum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | V | Less than maximum TEST LIMIT |
| $08 | Maximum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | V | More than minimum TEST LIMIT |
FRONT HO2S SLOW SLOPE MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard |
|---|---|---|---|---|
| $03 | Low sensor voltage for switch time calculation (constant) | Multiply by 0.005 | V | Same as TEST LIMIT. |
| $04 | High sensor voltage for switch time calculation (constant) | Multiply by 0.005 | V | Same as TEST LIMIT. |
FRONT HO2S SLOW SLOPE MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard |
|---|---|---|---|---|
| $31 | Average of Rich to Leen response time | Multiply by 0.04096 | Second | Between minimum and maximum TEST LIMIT. |
| $32 | Average of Rich to Leen response time | Multiply by 0.04096 | Second | Between minimum and maximum TEST LIMIT. |
FRONT HO2S FREQUENCY MONITOR
| TEST ID | Description of TEST DATA | Conversion Factor | Unit | Standard |
|---|---|---|---|---|
| $38 | Average time per cycle of HO2 sensor voltage | Multiply by 0.04096 | Second | Between minimum and maximum TEST LIMIT. |
REAR HO2S VOLTAGE MONITOR
| Test IDs | Description of TEST DATA | Conversion Factor | Units | Standard Values |
|---|---|---|---|---|
| $07 | Minimum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | Volt | Less than maximum TEST LIMIT |
| $08 | Maximum HO2 sensor (sensor 1) voltage | Multiply by 0.005 | Volt | More than minimum TEST LIMIT |
REAR HO2S MONITOR VOLTAGE
| Test IDs | Description of TEST DATA | Conversion Factor | Units | Standard Values |
|---|---|---|---|---|
| $31 | Average time for HO2 sensor (sensor 1) output to switch from Lean to Rich | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $32 | Average time for HO2 sensor (sensor 1) output to switch from Rich to Lean | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT. |
REAR HO2S SLOW RESPONSE MONITOR
| Test IDs | Description of TEST DATA | Conversion Factor | Units | Standard Values |
|---|---|---|---|---|
| $37 | Time until HO2 sensor voltage drops to 0.2 V during fuel-cut | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
| $39S | witch time for HO2 sensor voltage to drop from 0.35 V to 0.2 V during fuel-cut | Multiply by 0.04096 | Second | Less than maximum TEST LIMIT |
REAR H2OS ELEMENT MONITOR
| Test IDs | Description of TEST DATA | Conversion Factor | Units | Standard Values |
|---|---|---|---|---|
| $81 | Percentage of monitor time that HO2 sensor (sensor 2) voltage below 0.05V | Multiply by 0.390 | % | Less than TEST LIMIT |
| $84 | Percentage of monitor time that HO2 sensor (sensor 2) voltage 0.7 V or more | Multiply by 0.390 | % | More than TEST LIMIT |
| $85 | Continuous time that HO2 sensor (sensor 2) voltage 0.45 V or more | Multiply by 0.26214 | Second | More than TEST LIMIT |
| $87 | Percentage of monitor time that HO2 sensor (sensor 2) voltage 0.45 V or more | Multiply by 0.390 | % | More than TEST LIMIT |
TID $01: CATALYST - USING HO2S ON SENSOR 1 AND 2
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 0 | $01 | Multiply by 0.0078 [no dimension] | Catalyst deterioration level bank 1: Determined by waveforms of HO2S sensor 1 and sensor 2 | Malfunction criteria for catalyst deterioration |
TID $02: EVAP - VACUUM MONITOR
| TLT | CID | Unit Conversion | Description of Test Value | Description of Test Limit |
|---|---|---|---|---|
| 1 | $01 | Multiply by 0.0916 [mmHg] | Test value of EVAP VSV: Determined by fuel tank pressure change during vacuum introduction | Malfunction criteria for EVAP VSV |
| 1 | $02 | Multiply by 0.0458 subtract 2.93 [mmHg] | Test value of bypass VSV: Determined by fuel tank pressure change at switching over bypass VSV | Malfunction criteria for bypass VSV |
| 0 | $03 | Multiply by 0.0458 [mmHg] | Test value of 0.04 inch leak: Determined by fuel tank pressure change | Malfunction criteria for 0.04 inch leak |
| 0 | $04 | Multiply by 0.0458 [mmHg] | Test value of 0.02 inch leak: Determined by fuel tank pressure change | Malfunction criteria for 0.02 inch leak |
| 1 | $05 | Multiply by 0.0458 subtract 2.93 [mmHg] | Test value of canister closed valve (CCV): Determined by fuel tank pressure change at switching over CCV | Malfunction criteria for CCV |