LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2005 >> LS 430 >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> Starting System & Charging System >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

Starting & Charging - Service Data

Starter Rated voltage and output power 12 V 2.0 kW
No-load characteristics Current 100 A or less at 11.5 V
Brush length STD 15.0 mm (0.591 in.)
Minimum 9.0 mm (0.354 in.)
Spring installed load STD 21.5 to 27.5 N (2.2 to 2.8 kgf, 4.9 to 6.2 lbf)
Minimum 12.7 N (1.3 kgf, 2.9 lbf)
Commutator  
Diameter STD 35.0 mm (1.378 in.)
Minimum 34.0 mm (1.339 in.)
Undercut depth STD 0.7 mm (0.028 in.)
Minimum 0.2 mm (0.008 in.)
Circle runout Maximum 0.05 mm (0.0020 in.)
Yoke  
Shut coil resistance at 20°C (68°F) 1.5 to 1.9 Ω
Generator Rated output 12 V 100 A
Rotor coil resistance at 20°C (68°F) 2.1 to 2.5 Ω
Slip ring diameter 12.8 to 14.4 mm (0.504 to 0.567 in.)
Brush exposed length 1.5 to 11.5 mm (0.059 to 0.453 in.)
Voltage regulator Regulating voltage 13.2 to 14.8 V