Charging Systems: Charging: Generator: Inspection
- INSPECT GENERATOR ROTOR
- Check if the rotor has an open circuit.
- Using an ohmmeter, measure the resistance between the slip rings.
Standard: 2.3 to 2.7 Ω at 20°C (68°F)
If the resistance is not as specified, replace the rotor.
- Using an ohmmeter, measure the resistance between the slip rings.
- Check if the rotor is grounded.
Using an ohmmeter, check the resistance between the slip ring and the rotor core.
Standard: 10 kΩ or higher
If the resistance is not as specified, replace the rotor.
- Check that the slip rings are not rough or scored.
If rough or scored, replace the rotor.
- Using a vernier caliper, measure the slip ring diameter.
Specified diameter:
14.2 to 14.4 mm (0.559 to 0.567 in.)
If the diameter is less than the minimum, replace the rotor.
- Check if the rotor has an open circuit.
- INSPECT BRUSH HOLDER
Using a vernier caliper, measure the exposed brush length.
Standard exposed brush length:
10.5 mm (0.413 in.)
Minimum exposed brush length: 4.5 mm (0.177 in.)
If the exposed brush length is less than the minimum, replace the holder.
- INSPECT BEARING
Check that the bearing is not rough or worn.
If necessary, replace the generator rotor.