Service Data

Battery Specific gravity at 20°C (68°F) 1.25 to 1.29
Voltage at 20°C (68°F) 12.5 to 12.9 V
Generator Rated output 12V 130A
Rotor coil resistance at 20°C (68°F) 2.3 to 2.7 Ω
Slip ring diameter STD 14.2 to 14.4 mm (0.559 to 0.567 in.)
Brush exposed length STD 10.5 mm (0.413 in.)
Minimum 4.5 mm (0.177 in.)
Charging circuit Without load STD amperage 10 A or less
STD voltage 13.2 to 14.8 V
With load STD amperage 30 A or less