LS 430
HO2S BANK 1 SENSOR 1 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $41 | $90 | Multiply by 0.001 [A] | Maximum sensor heater current | Minimum test limit | Maximum test limit |
HO2S BANK 1 SENSOR 2 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $42 | $90 | Multiply by 0.001 [A] | Maximum sensor heater current | Minimum test limit | Maximum test limit |
HO2S BANK 2 SENSOR 1 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $45 | $90 | Multiply by 0.001 [A] | Maximum sensor heater current | Minimum test limit | Maximum test limit |
HO2S BANK 2 SENSOR 2 HEATER
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $46 | $90 | Multiply by 0.001 [A] | Maximum sensor heater current | Minimum test limit | Maximum test limit |
THERMOSTAT
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $E1 | $E8 | Multiply by 0.1 [°C] | ECT sensor output when estimated ECT reached to malfunction criteria | Malfunction criteria | Maximum test limit |
HO2S BANK 1 SENSOR 1
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $01 | $03 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Lean that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Lean | Sensor voltage to define sensor status is Lean |
| $01 | $04 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Rich that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Rich | Sensor voltage to define sensor status is Rich |
| $01 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | Minimum test limit | Maximum test limit |
| $01 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | Minimum test limit | Maximum test limit |
| $01 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | 0 V | Malfunction criterion |
| $01 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Malfunction criterion | 1.0 V |
| $01 | $81 | Multiply by 0.001 [seconds] | Duration while sensor voltage stuck Lean or Rich | 0 | Malfunction criterion |
| $01 | $82 | Multiply by 0.001 [seconds] | Duration of one sensor frequency | Minimum test limit | Maximum test limit |
HO2S BANK 2 SENSOR 1
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $05 | $03 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Lean that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Lean | Sensor voltage to define sensor status is Lean |
| $05 | $04 | Multiply by 0.001 [V] | Sensor voltage to define sensor status is Rich that is defined when sensor voltage is lower than this value | Sensor voltage to define sensor status is Rich | Sensor voltage to define sensor status is Rich |
| $05 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | Minimum test limit | Maximum test limit |
| $05 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | Minimum test limit | Maximum test limit |
| $05 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | 0 V | Malfunction criterion |
| $05 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Malfunction criterion | 1.0 V |
| $05 | $81 | Multiply by 0.001 [seconds] | Duration while sensor voltage stuck Lean or Rich | 0 | Malfunction criterion |
| $05 | $82 | Multiply by 0.001 [seconds] | Duration of one sensor frequency | Minimum test limit | Maximum test limit |
HO2S BANK 1 SENSOR 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $02 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | 0 | Malfunction criterion |
| $02 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | 0 | Malfunction criterion |
| $02 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | Minimum test limit | Maximum test limit |
| $02 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Minimum test limit | Maximum test limit |
| $02 | $84 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was lower than 0.05 V | 0 | Malfunction criterion |
| $02 | $85 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was higher than 0.7 V | Malfunction criterion | 65,535 |
| $02 | $86 | Multiply by 0.1 [seconds] | Duration while sensor voltage was higher than 0.7 V | 0 | 65,535 |
| $02 | $87 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was higher than 0.45 V | Minimum test limit | 65,535 |
| $02 | $88 | Multiply by 0.1 [seconds] | Cumulative time that sub-feedback compensation factor remained 7 % or more | 0 | Malfunction criterion |
| $02 | $89 | Multiply by 0.01526 [%] | Percentage in monitor time when sub-feedback compensation factor remained 0.05 V or more | 0 | Malfunction criterion |
| $02 | $8A | Multiply by 1 [time] | Frequency of sensor switching | 0 | Malfunction criterion |
| $02 | $8B | Multiply by 0.001 [seconds] | 0.35 V to 0.2 V sensor switch time | 0 | Maximum test limit |
| $02 | $8D | Multiply by 0.001 [seconds] | Duration that sensor voltage dropped to 0.2 V during fuel-cut | 0 | Malfunction criterion |
| $02 | $8F | Multiply by 0.001 [g] | Maximum oxygen storage capacity | 0 | Maximum test limit |
HO2S BANK 2 SENSOR 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $06 | $05 | Multiply by 0.001 [seconds] | Rich to Lean switch time | 0 | Malfunction criterion |
| $06 | $06 | Multiply by 0.001 [seconds] | Lean to Rich switch time | 0 | Malfunction criterion |
| $06 | $07 | Multiply by 0.005 [V] | Minimum sensor voltage | Minimum test limit | Maximum test limit |
| $06 | $08 | Multiply by 0.005 [V] | Maximum sensor voltage | Minimum test limit | Maximum test limit |
| $06 | $84 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was lower than 0.05 V | 0 | Malfunction criterion |
| $06 | $85 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was higher than 0.7 V | Malfunction criterion | 65,535 |
| $06 | $86 | Multiply by 0.1 [seconds] | Duration while sensor voltage was higher than 0.7 V | 0 | 65,535 |
| $06 | $87 | Multiply by 0.01526 [%] | Percentage in monitor time when sensor voltage was higher than 0.45 V | Minimum test limit | 65,535 |
| $06 | $88 | Multiply by 0.1 [seconds] | Cumulative time that sub-feedback compensation factor remained 7 % or more | 0 | Malfunction criterion |
| $06 | $89 | Multiply by 0.01526 [%] | Percentage in monitor time when sub-feedback compensation factor remained 0.05 V or more | 0 | Malfunction criterion |
| $06 | $8A | Multiply by 1 [time] | Frequency of sensor switching | 0 | Malfunction criterion |
| $06 | $8B | Multiply by 0.001 [seconds] | 0.35 V to 0.2 V sensor switch time | 0 | Maximum test limit |
| $06 | $8D | Multiply by 0.001 [seconds] | Duration that sensor voltage dropped to 0.2 V during fuel-cut | 0 | Malfunction criterion |
| $06 | $8F | Multiply by 0.001 [g] | Maximum oxygen storage capacity | 0 | Maximum test limit |
MISFIRE MONITOR - ALL CYLINDERS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A1 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A1 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - CYLINDER 1
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A2 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A2 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - CYLINDER 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A3 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A3 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - CYLINDER 3
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A4 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A4 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - CYLINDER 4
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A5 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A5 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - CYLINDER 5
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A6 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A6 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - CYLINDER 6
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A7 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A7 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - CYLINDER 7
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A8 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A8 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
MISFIRE MONITOR - CYLINDER 8
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $A9 | $0B | Multiply by 1 [time] | Exponential Weighted Moving Average misfire counts for last 10 driving cycles - total | 0 | 65,535 |
| $A9 | $0C | Multiply by 1 [time] | Misfire counts for last and current driving cycles - total | 0 | 65,535 |
CATALYST BANK 1 - USING HO2S ON SENSOR 1 AND 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $21 | $A1 | Multiply by 0.0003 [no dimension] | Locus length ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A2 | Multiply by 0.0003 [no dimension] | Voltage area ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A3 | Multiply by 0.0003 [no dimension] | Locus length ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A4 | Multiply by 0.0003 [no dimension] | HO2S frequency ratio of sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A5 | Multiply by 0.0003 [no dimension] | Locus length ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $21 | $A6 | Multiply by 0.0003 [no dimension] | Voltage area ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
CATALYST BANK 2 - USING HO2S ON SENSOR 1 AND 2
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $22 | $A1 | Multiply by 0.0003 [no dimension] | Locus length ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A2 | Multiply by 0.0003 [no dimension] | Voltage area ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A3 | Multiply by 0.0003 [no dimension] | Locus length ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A4 | Multiply by 0.0003 [no dimension] | HO2S frequency ratio of sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A5 | Multiply by 0.0003 [no dimension] | Locus length ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
| $22 | $A6 | Multiply by 0.0003 [no dimension] | Voltage area ratio of HO2S sensor 1 and sensor 2 | Minimum test limit for catalyst | Maximum test limit for catalyst |
EVAP - VACUUM MONITOR
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $3B | $C1 | Multiply by 0.01 [kPa] | Test value of 0.02 inch leak: Determined by fuel tank pressure change at 0.02 inch leak check | Minimum test limit for 0.02 inch leak | Maximum test limit for 0.02 inch leak |
| $3C | $C2 | Multiply by 0.01 [kPa] | Test value of 0.04 inch leak: Determined by fuel tank pressure change at 0.04 inch leak check | Minimum test limit for 0.04 inch leak | Maximum test limit for 0.04 inch leak |
| $3D | $C6 | Multiply by 0.001 [kPa] | Test value of purge VSV: Determined by fuel tank pressure change during vacuum introduction | Minimum test limit for purge VSV | Maximum test limit for purge VSV |
| $3D | $C7 | Multiply by 0.001 [kPa] | Test value of Canister Closed Valve (CCV): Determined by fuel tank pressure change at switching over CCV | Minimum test limit for CCV | Maximum test limit for CCV |
| $3D | $C8 | Multiply by 0.001 [kPa] | Test value of bypass VSV: Determined by fuel tank pressure change at switching over bypass VSV | Minimum test limit for bypass VSV | Maximum test limit for bypass VSV |