TID $04 HO2S HEATER

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 1) Malfunction criterion
1 $02 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 1 Sensor 2) Malfunction criterion
1 $10 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 2 Sensor 1) Malfunction criterion
1 $20 Multiply by 0.000076 [A] Maximum HO2S heater current (Bank 2 Sensor 2) Malfunction criterion
TID $08 THERMOSTAT

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.625 and subtract 40 [°C] ECT sensor output when estimated ECT reaches malfunction criterion Malfunction criterion for thermostat
O2S TEST RESULT

TID Unit Conversion Description of Test Value Malfunction Criteria
$03 Multiply by 0.005 [V] This value is used to calculate TID $31 and $32 -
$04 Multiply by 0.005 [V] This value is used to calculate TID $31 and $32 -
$07 Multiply by 0.005 [V] Minimum sensor voltage Less than 0.4 V
$08 Multiply by 0.005 [V] Maximum sensor voltage More than 0.55 V
$31 Multiply by 0.04 [seconds] Lean to Rich switch time Less than 0.9 seconds
$32 Multiply by 0.04 [seconds] Rich to Lean switch time Less than 0.9 seconds
$38 Multiply by 0.04 [seconds] Average of switching frequency Varies with operating conditions
O2S TEST RESULT

TID Unit Conversion Description of Test Value Malfunction Criteria
$07 Multiply by 0.005 [V] Minimum sensor voltage Less than 0.4 V
$08 Multiply by 0.005 [V] Maximum sensor voltage More than 0.55 V
$31 Multiply by 0.04 [seconds] Lean to Rich switch time -
$32 Multiply by 0.04 [seconds] Rich to Lean switch time -
$37 Multiply by 0.04 [seconds] Rich to Lean switch time during fuel-cut -
$81 Multiply by 0.39 [%] Percentage in monitor time that sensor voltage is less than 0.05 V 60% or more
$84 Multiply by 0.39 [%] Percentage in monitor time that sensor voltage is more than 0.7 V 20% or less
$81 Multiply by 0.26 [seconds] Duration that sensor voltage is 0.45 V or higher 20 seconds or less
$81 Multiply by 0.39 [%] Percentage in monitor time that sensor voltage is more than 0.45 V 25% or less
TID +$01: CATALYST - USING HO2S ON SENSOR 1 AND 2

TLT CID Unit Conversion Description of Test Value Description of Test Limit
0 $01 Multiply by 0.0078 [no dimension] Catalyst deterioration level bank 1: Determined by waveforms of HO2S sensor 1 and sensor 2 Malfunction criteria for catalyst deterioration
0 $02 Multiply by 0.0078 [no dimension] Catalyst deterioration level bank 2: Determined by waveforms of HO2S sensor 1 and sensor 2 Malfunction criteria for catalyst deterioration
TID $02 EVAP - VACUUM MONITOR

TLT CID Unit Conversion Description of Test Value Description of Test Limit
1 $01 Multiply by 0.0916 [mmHg] Test value of EVAP VSV: Determined by fuel tank pressure change during vacuum introduction Malfunction criteria for EVAP VSV
1 $02 Multiply by 0.0458 subtract 2.93 [mmHg] Test value of bypass VSV: Determined by fuel tank pressure change at switching over bypass VSV Malfunction criteria for bypass VSV
0 $03 Multiply by 0.0458 [mmHg] Test value of 0.04 inch leak: Determined by fuel tank pressure change Malfunction criteria for 0.04 inch leak
0 $04 Multiply by 0.0458 [mmHg] Test value of 0.02 inch leak: Determined by fuel tank pressure change Malfunction criteria for 0.02 inch leak
0 $05 Multiply by 0.0458 subtract 2.93 [mmHg] Test value of canister closed valve (CCV): Determined by fuel tank pressure change at switching over CCV Malfunction criteria for CCV