Monitor Result
Refer to detailed information (see CHECKING MONITOR STATUS ).
The test value and test limit information are described as shown in the following table. Check the monitor result and test values after performing the monitor drive pattern (refer to "CONFIRMATION DRIVING PATTERN ").
- Monitor Identification Data (MID) is assigned to each emissions-related component.
- Test Identification Data (TID) is assigned to each test value.
- Scaling is used to calculate the test value indicated on generic OBD II scan tools.
Thermostat
THERMOSTAT SPECIFICATIONS
| MID | TID | Scaling | Description of Test Value | Minimum Test Limit | Maximum Test Limit |
|---|---|---|---|---|---|
| $E1 | $E8 | Multiply by 01 [°C] | ECT sensor output when estimated ECT reaches to malfunction criteria | Malfunction criteria | Maximum test limit |