Typical Malfunction Thresholds
TYPICAL MALFUNCTION THRESHOLDS
| Either of the following conditions is met: | Condition 1 or 2 |
| 1. Frequency that both of the following conditions (a) and (b) are met: | 5 times or more |
| (a) Engine RPM - target engine RPM | Less than -100 rpm or more than 150 rpm |
| (b) Vehicle condition | Stop after vehicle was driven by 10 km/h (6.25 mph) or more |
| 2. Frequency that both of the following conditions (a) and (b) are met: | Once |
| (a) Engine RPM - target engine RPM | Less than -100 rpm or more than 150 rpm |
| (b) Intake air control flow rate learning value | 2.48 L/sec. or less, or 11 L/sec. or more |