BRAKE CONTROL SERVICE DATA SPECIFICATION
| Traction OFF switch | Resistance 3 - 4 | Pressed | Below 1 ohms |
| Not pressed | 10 k ohms or higher | ||
| Brake pedal load sensing switch | Resistance 1 - 2 | Brake pedal depressed | 0.9 to 1.1 k ohms |
| Brake pedal released | 192 to 234 ohms | ||
| ABS motor1 relay | Resistance 1 - 2 | Below 1 ohms | |
| Resistance 3 - 5 | When battery voltage is not applied between terminals | 10 k ohms or higher | |
| When battery voltage is applied to terminals 1 and 2 | Below 1 ohms | ||
| ABS motor2 relay | Resistance 1 - 2 | Below 1 ohms | |
| Resistance 3 - 5 | When battery voltage is not applied between terminals | 10 k ohms or higher | |
| When battery voltage is applied to terminals 1 and 2 | Below 1 ohms | ||
| Stop light control relay | Resistance 1 - 2 | Below 1 ohms | |
| Resistance 3 - 4 | When battery voltage is not applied between terminals | Below 1 ohms | |
| When battery voltage is applied to terminals 1 and 2 | 10 k ohms or higher | ||
| Resistance 3 - 5 | When battery voltage is not applied between terminals | 10 k ohms or higher | |
| When battery voltage is applied to terminals 1 and 2 | Below 1 ohms | ||
| ABS solenoid relay (with VDIM) | Resistance 1 - 2 | Below 1 ohms | |
| Resistance 3 - 5 | When battery voltage is not applied between terminals | 10 k ohms or higher | |
| When battery voltage is applied to terminals 1 and 2 | Below 1 ohms | ||