LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2006 >> IS 350 >> Repair and Diagnosis >> Engine Performance >> Engine Control System (2GR-FSE) >> SFI System >> DTC P0441 Evaporative Emission Control System Incorrect Purge Flow >> DTC Summary
April 5, 2026: LEMON Manuals is launched! Read the announcement.

DTC Summary

DTC DETECTION CONDITION AND TROUBLE AREA

DTC No. Monitoring Item DTC Detection Condition Trouble Area Detection Timing Detection Logic
P0441 EVAP VSV (Vacuum Switching Valve) stuck open Vacuum pump creates negative pressure (vacuum) in EVAP system and EVAP system pressure measured. 0.02 inch leak pressure standard measured at start and at end of leak check. If stabilized pressure higher than [second 0.02 inch leak pressure standard x 0.2], ECM determines that EVAP VSV stuck open
  • EVAP VSV
  • Connector/wire harness (EVAP VSV - ECM)
  • ECM
  • Pump module
  • Leakage from EVAP system
While engine switch off 2 trip
P0441 EVAP VSV stuck closed After EVAP leak check performed, EVAP VSV turned ON (open), and atmospheric air introduced into EVAP system. 0.02 inch leak pressure standard measured at start and at end of the check.
If pressure does not return to near atmospheric pressure, ECM determines that purge valve stuck closed
  • EVAP VSV
  • Connector/wire harness (EVAP VSV - ECM)
  • ECM
  • Pump module
  • Leakage from EVAP system
While engine switch off 2 trip
P0441 Purge flow While engine running, following conditions are successively met:
  • Negative pressure not created in EVAP system when EVAP VSV turned ON (open)
  • EVAP system pressure change less than 0.5 kPa (3.75 mmHg) when vent valve turned ON (closed)
  • Atmospheric pressure change before and after purge flow monitor less than 0.1 kPa (0.75 mmHg)
  • EVAP VSV
  • Connector/wire harness (EVAP VSV - ECM)
  • Leakage from EVAP line (EVAP VSV - Intake manifold)
  • ECM
While engine running 2 trip