LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2006 >> RX 330 AWD >> Repair and Diagnosis >> Electrical >> Starter >> Starting - Service Specifications >> 3MZ-FE Starting >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

SERVICE DATA SPECIFICATION (3MZ-FE STARTING)

Starter
Specified current:
90 A or less at 11.5 V
Starter relay
Specified condition:
3 - 5: 10 kΩ or higher
3 - 5: Below 1 Ω(Applying battery voltage terminals 1 and 2)
Starter armature assembly
Depth:
STD: 3.1 mm (0.122 in.)
Maximum: 3.8 mm (0.150 in.)
Starter commutator end frame assembly
Brush length
STD: 9.0 mm (0.354 in.)
Minimum: 4.0 mm (0.158 in.)
Ignition Switch LOCK: Between all terminals 10 kΩ or higher
ACC: 2 - 3 Below 1 Ω
ON: 2 - 3 Below 1 Ω
ON: 2 - 4 Below 1 Ω
ON: 6 - 7 Below 1 Ω
START: 1 - 2 Below 1 Ω
START: 2 - 4 Below 1 Ω
START: 6 - 7 Below 1 Ω
START: 7 - 8 Below 1 Ω