LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2006 >> RX 330 FWD >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging - Service Specifications >> 3MZ-FE Charging >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

SERVICE DATA SPECIFICATION (3MZ-FE CHARGING)

Battery
Except maintenance-free battery
Standard specific gravity: 1.25 to 1.29 at 20°C (68°F)
Battery Voltage: 12.6 to 12.8 V at 20°C (68°F)
Voltage regulator Regulating voltage: 13.2 to 14.8 V
Standard amperage: 10 A or less
Generator brush holder assembly
Brush length
Standard: 10.5 mm (0.413 in.)
Minimum: 4.5 mm (0.177 in.)
Generator rotor assembly
Open circuit
Resistance: 2.3 to 2.7 Ω at 20°C (68°F) for 100 A Generator
Resistance: 1.5 to 1.9 Ω at 20°C (68°F) for 130 A Generator
Generator rotor assembly
Slip ring diameter
Standard: 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum: 14.0 mm (0.551 in.)