Monitor Strategy
MONITOR STRATEGY
| Related DTCs | P0116: ECT sensor stuck P0116: ECT sensor stuck at high ECT |
| Required sensors/ components (Main) | ECT sensor |
| Required sensors/ components (Related) | Crankshaft position sensor, IAT sensor, MAF meter |
| Frequency of operation | Continuous |
| Duration | 250 seconds or more |
| MIL operation | 2 driving cycles: ECT sensor stuck 6 driving cycles: ECT sensor stuck at high ECT |
| Sequence operation | None |