Ignition Relay No. 2: Inspection
- INSPECT IGNITION RELAY NO. 2
- Using an ohmmeter, measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 3 - 5 10 kΩ or higher 3 - 5 Below 1 Ω (Battery voltage applied between terminals 1 and 2) If the result is not as specified, replace the relay.
- Using an ohmmeter, measure the resistance according to the value(s) in the table below.