Typical Enabling Conditions
All:
TYPICAL ENABLING CONDITIONS
| The monitor will run whenever this DTC is not present. | None |
| Engine switch | ON |
| Battery voltage | 10.5 V or more |
Condition (C):
TYPICAL ENABLING CONDITIONS
| One of the following conditions is met: | Condition (a) or (b) |
| (a) Park Neutral position switch | ON |
| (b) R range position switch | ON |