Inspection Procedure
- PERFORM INITIALIZATION
- Initialize the power window regulator motor assembly (applicable location) (See CUSTOMIZE PARAMETERS ).
- Check if the power window AUTO UP/DOWN function operates normally.
OK:
AUTO UP/DOWN function operates normally.
NG : END (PROBLEM DUE TO INITIALIZATION FAILURE)
OK : Go to Next Step
- CHECK JAM PROTECTION FUNCTION OPERATING RANGE
- Check if the jam protection function operates normally for the applicable power window.
HINT:
The jam protection function will not operate within 4 mm (0.157 in) of the fully closed position.
OK:
Jam protection function operates normally.
Result
RESULT CHARTResult Proceed to OK A NG (Front LH side power window) B NG (Front RH side power window) C NG (Rear LH side power window) D NG (Rear RH side power window) E
B : REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (See REMOVAL )
C : REPLACE FRONT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (See REMOVAL )
D : REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY LH (See REMOVAL )
E : REPLACE REAR POWER WINDOW REGULATOR MOTOR ASSEMBLY RH (See REMOVAL )
A : END
- Check if the jam protection function operates normally for the applicable power window.