LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2008 >> GS 350 AWD >> Repair and Diagnosis >> General Information >> OEM General Information >> Service Specifications >> 1UR-FSE Cooling System >> Service Data
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Service Data

SERVICE DATA - 1UR-FSE COOLING

Cooling fan motor Standard current
2 to 12 A
(when the A/C switch is turned ON (MAX COOL and the magnetic clutch is operating)
Standard current
14.7 to 18.7A at 20°C (68°F)
(when the battery is connected to the fan motor connector)
Standard current
2 to 18.1 A
(when the engine coolant temperature sensor connector is disconnected)
No. 2 cooling fan motor Standard current
2 to 12 A
(when the A/C switch is turned ON (MAX COOL and the magnetic clutch is operating)
Standard current
14.7 to 18.7A at 20°C (68°F)
(when the battery is connected to the fan motor connector)
Standard current
2 to 18.1 A
(when the engine coolant temperature sensor connector is disconnected)
Water inlet sub-assembly with thermostat Valve opening temperature 80 to 84°C (176 to 183°F)
Valve lift
10.0 mm (0.394 in.) or more at 95°C (203°F)
Cooling fan relay 3-5:10 MΩ or higher
3 - 5: Below 1 Ω
(when battery voltage is applied to terminals 1 and 2)
Cooling fan ECU Standard voltage
11 to 14 V
(when turn the engine switch on (IG))