Inspection Mode Procedure
HINT:
Before reading the Data List or performing the Active Test using the Techstream, be sure to put the system into the inspection mode using the following procedure.
- ACTIVATING INSPECTION MODE
- Not using the Techstream
- Perform the following steps in 60 seconds.
- Turn the power switch on (IG).
- Fully depress the accelerator pedal twice with the transmission in the P position.
- Fully depress the accelerator pedal twice with the transmission in the N position.
- Fully depress the accelerator pedal twice with the transmission in the P position.
- Check that the "MAINTENANCE MODE" on the multi-information display is illuminated in the combination meter.
- Turn the power switch on (READY).
- To end inspection mode, turn the power switch off.
- Perform the following steps in 60 seconds.
- Not using the Techstream